|
Build Your Online Product Catalogs?
Product Name: |
300/500V SR Insulated LSZH Sheathed Fire Alarm Cables
|
Supply Ability: |
|
Related proudcts |
|
Specifications |
300/500V SR Insulated LSZH Sheathed Fire Alarm Cables,Fire Resistant Fire Alarm Cables |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
300/500V SR Insulated & LSZH Sheathed Fire Alarm CablesFR200P 2GSH-U (PH30) (CU/SR/OS/LSZH 300/500V Class 1)FR200P 2GSH-R (PH30) (CU/SR/OS/LSZH 300/500V Class 2)Application:The cables are designed,Website:http://www.ue-cable.com, manufactured and tested as data transmission cables for emergency services. These are primarily intended for for indoor instrumentation and control cabling, electrically noisy environments and fire alarm systems in office buildings when high frequency signal transmission has to be assured in the event of a fire.STANDARDS:Basic design to BS 7629-1FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)Circuit Integrity with mechanical shockEN 50200(PH30); CEI 20-36/4-0Circuit Integrity with mechanical shock & water sprayEN 50200 annex ESystem circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.CABLE CONSTRUCTION Conductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1, stranded according to IEC(EN) 60228 class 2.Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.Cabling Elements: Insu |
Company: |
UNIVERSAL CABLES LIMITED
|
Contact: |
Ms. Helen Wong |
Address: |
1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China |
Postcode: |
250101 |
Tel: |
86-531-88817113 |
Fax: |
86-531-88819113 |
E-mail: |
|
|
|
|