|
UNIVERSAL CABLES LIMITED
Products >> 300/500V Mica+XLPE Or SR Insulated Overall Screened Multicore Fire Resistant Instrumentation Cables
Build Your Online Product Catalogs?
Product Name: |
300/500V Mica+XLPE Or SR Insulated Overall Screened Multicore Fire Resistant Instrumentation Cables
|
Supply Ability: |
|
Related proudcts |
|
Specifications |
300/500V Mica+XLPE Or SR Insulated Overall Screened Multicore Fire Resistant Instrumentation Cables,Fire Resistant Instrumention Cables |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
300/500V Mica+XLPE or SR Insulated & Overall screened Multicore fire resistant Instrumentation cablesRE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OS/LSZH 300/500V Class 2 )RE-2G(St)H...CI. FE 180 PH30 ( CU/SR/OS/LSZH 300/500V Class 2 )RE-2X(St)HSWAH...CI. FE 180 PH30 ( CU/MGT+XLPE/OS/LSZH/SWA/LSZH 300/500V Class 2 )RE-2G(St)HSWAH...CI. FE 180 PH30 ( CU/SR/OS/LSZH/SWA/LSZH 300/500V Class 2 )Application:These cables are designed,Website:http://www.ue-cable.com, manufactured and tested as data transmission cables for emergency services. These are used for data and voice transmission when high frequency signal has to be assured also in the event of a fire.STANDARDS:Basic design to BS 5308/BS 7629-1FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)Circuit Integrity with mechanicalshockEN 50200(PH30); CEI 20-36/4-0Circuit Integrity with mechanicalshock & water sprayEN 50200 annex ESystem circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING300/500 VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.I |
Company: |
UNIVERSAL CABLES LIMITED
|
Contact: |
Ms. Helen Wong |
Address: |
1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China |
Postcode: |
250101 |
Tel: |
86-531-88817113 |
Fax: |
86-531-88819113 |
E-mail: |
|
|
|
|