|
Build Your Online Product Catalogs?
Product Name: |
Fire Resistant UTP CAT5 Data Cables
|
Supply Ability: |
|
Related proudcts |
|
Specifications |
Fire Resistant UTP CAT5 Data Cables,Fire Resistant Signal And Data Cables |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
Fire Resistant UTP CAT5 Data Cables FR-CAT5UTP4P24Application:The cables are desgined for structure wiring,Website:http://www.ue-cable.com, co***tible with all known connection systems according to EN 50173. Based on the design for structured wiring (found in IEC 61156 and BS EN 50288), this cable brings together high frequency data transmission and circuit integrity in four pair cable that will continue to transmit data even when being directly attacked by fire.STANDARDS:Basic design to EN 50173VOLTAGE RATING:60VFIRE PERFORMANCECircuit IntegrityIEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.CABLE CONSTRUCTIONConductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1.Insulation: PE wrapped with fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimizecrosstalk.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimizecrosstalk. Two-pair cable had four cores laid in quad formation.Cabling: Pairs are cabled toge |
Company: |
UNIVERSAL CABLES LIMITED
|
Contact: |
Ms. Helen Wong |
Address: |
1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China |
Postcode: |
250101 |
Tel: |
86-531-88817113 |
Fax: |
86-531-88819113 |
E-mail: |
|
|
|
|